PC Strand is a steel wire product made of multiple strands of steel wire that are reasonably arranged and twisted. It has the characteristics of high strength, corrosion resistance and wear resistance, and has been widely used in modern industrial and civil fields.
Application:
1. Bridge construction: PC Strand plays a vital role in the strength and stability of bridges. It can not only enhance the mechanical strength of the steel structure, but also improve the durability of the steel structure and extend the service life of the building.
2. Tunnel engineering: During the tunnel forming and transportation process, PC Strand can reinforce and stabilize the soil. At the same time, it can also prevent bumps and landslides in the soil when transport vehicles pass through, ensuring the safe operation of the tunnel project.
3. Building structure: In building structures, PC Strand can play a role in connection and reinforcement. Especially in high-rise buildings and large public buildings, PC Strand can not only enhance the effectiveness of steel structures, but also reduce the safety of buildings. Hidden danger.
4. Aerospace: In the aerospace field, PC Strand plays an important role in manufacturing aircraft landing gear, engines, wings and other components. It has the characteristics of lightweight, high strength and corrosion resistance, which can improve the operational efficiency and safety of aircraft.
5. Rail transit: In the fields of rail transit such as subways and high-speed rails, PC Strand is used to manufacture tracks, traffic networks, catenaries and signaling equipment. It can improve the safety and reliability of rail transportation and ensure efficient operation of transportation.
Product Parameters:
PC Strand ASTM A416 |
||||||||
Structure |
Rank |
Nominal diameter (mm) |
Sectional area (mm²) |
Weight breaking force (KN) |
1000H Relaxation value % ≤ |
|||
Minimum breaking force (KN) |
Elongation ≥ (KN) |
Initial load is 70% nominal maximum load |
Initial load is 80% nominal maximum load |
|||||
1X7 |
250 |
6.40 |
23.2 |
182 |
40.00 |
3.5 |
2.5 |
3.5 |
7.90 |
37.4 |
294 |
64.50 |
|||||
9.50 |
51.6 |
405 |
89.00 |
|||||
11.10 |
69.7 |
548 |
120.10 |
|||||
12.70 |
92.9 |
730 |
160.10 |
|||||
15.20 |
139.4 |
1094 |
240.10 |
|||||
270 |
9.53 |
58.4 |
432 |
102.30 |
3.5 |
2.5 |
3.5 |
|
11.11 |
74.2 |
582 |
137.90 |
|||||
12.70 |
98.7 |
775 |
183.70 |
|||||
13.20 |
107.7 |
844 |
200.20 |
|||||
15.24 |
140 |
1102 |
260.70 |